VEGAPULS 64 Waste Tank CHT TLI
Description
Technical Specifications
Technical Data | |
Measuring Range | 30 m (98.43 ft) |
Process Fitting | Thread from G¾, ¾NPT, flanges from DN 50, 2”, mounting strap, adapter flanges from DN 100, 4” |
Deviation | ≤ 1 mm |
Environmental | |
Process Pressure | -1 to 25 bar (-100 to 2500 kPa/ -14.5 to 362.6 psig) |
Process Temperature | -196 to +200 °C (-321 to +392 °F) |
Ambient, storage, and transport temperature |
-40 to +80 °C (-40 to +176 °F) |
Electrical | |
Operating Voltage | 12 to 35 VDC |
Electonics Versions | 4 to 20 mA/HART HART Power Pack |
Materials | |
Wetted Parts | 316L, PP, PTFE, or PEEK |
Display | LCD in dot matrix |
Process Seal | FKM, FFKM, EPDM, or PTFE |
Housing | Plastic, Stainless Steel, or Aluminum |
Protection Rating | Up to IP68 (1 bar) |